Overview
Power-handling equipment—think switchgears, transformers, electrical panels, uninterruptable power supplies—are all vital infrastructure to business and industry. In the data-center world, this backend equipment resides in what is known as the “gray space.”
A failure in this mission-critical infrastructure can lead to costly downtime, lost productivity, and possibly a fire or explosion. The problem with electrical equipment is that it often operates for years or even decades with no hint of a problem until it suddenly fails catastrophically without warning.
To avoid this, companies have traditionally been left with only one choice: time-consuming manual inspections to check connections, examine the condition of the equipment, and using a handheld infrared (IR) gun to look for hotspots. While this plan has merit, it depends on the skill of the inspector and organization’s commitment to performing the inspections.
Fireaway is now offering a total fire protection solution for operators through their new line of Ultrasense™ Power Generation sensors. Fireaway produces Stat-X®, a condensed aerosol fire suppression agent that is proven effective on electrical equipment fire incidents. When paired with their suite of UltraSense sensors, Fireaway’s Stat-X fire suppression system offers operators a complete protection package that includes prevention, detection, and suppression.

Electrical Equipment Failure
Before delving into the protection features provided by UltraSense sensors, it is important to understand how electrical equipment such as transformers, switchgears, and electrical panels fail. Once the failure mode initiates, if left unchecked, it can lead to a self-propagating, chain-reaction-like event which can result in a devastating fire or explosion. For brevity, this will be referred to as the “failure chain reaction” hereafter.
Environmental Factors
Dust and condensation from humidity or water ingress can accumulate in electrical equipment, causing partial shorts, arcing, and increased resistance. These conditions can generate heat, especially under high voltage, and lead to localized hotspots that initiate a failure chain reaction.
Aging and Lack of Maintenance
Over time, components in electrical equipment can degrade due to mechanical wear, environmental exposure, and repeated heating and cooling cycles. Without regular maintenance, these aging parts are more susceptible to failure, which can lead to overheating and, ultimately, a failure chain reaction.
Poor Ventilation or Cooling
Electrical equipment enclosures that lack proper ventilation or cooling may struggle to dissipate the heat generated by normal or abnormal operation. If the heat buildup inside the enclosure exceeds the thermal tolerance of its components, it can trigger a failure chain reaction as parts begin to overheat and fail sequentially.
Manufacturing Defects
Improper insulation, defective components, inadequate clearances, and improper assembly can all lead to internal arcing—when an electrical arc forms inside of electrical equipment, generating intense localized heat. Arcing can ignite surrounding materials, causing rapid temperature increases and leading to a chain reaction of failure in other components.
Insulation Degradation
The insulation material in electrical equipment can degrade over time, especially if exposed to high temperatures, moisture, or other environmental factors. Damaged or degraded insulation can lead to partial discharges, arcing, or short circuits, all of which generate heat. If this heat is not dissipated, it can cause nearby components to overheat and fail, contributing to a failure chain reaction.
Overcurrent Conditions
If electrical equipment experiences excessive current, such as from a fault condition or overload, it can generate significant heat in conductors and contacts. This heat buildup can lead to the breakdown of insulation and other protective materials, escalating to a failure chain reaction if not managed.
Loose Connections or Faulty Contacts
Loose connections or degraded contact surfaces within electrical equipment create areas of high electrical resistance; this generates heat when current flows through them. Over time, this heating effect can worsen, especially under high-load conditions, causing the components to overheat and potentially leading to failure chain reaction.
Failure Chain Reaction in Electrical Equipment
During a failure chain reaction in electrical equipment, a rapid, self-sustaining increase in temperature occurs, leading to a series of potentially dangerous events. In this context, failure chain reactions typically follow this course of events:
- Overheating of Components
Initially, certain components—such as connectors, busbars, or insulation—overheat due to high resistance, poor connections, or fault conditions. The excessive heat begins to weaken nearby components, exacerbating the thermal buildup. - Accelerated Degradation of Insulation and Materials
As temperatures rise, the insulation materials and plastic components within the electrical equipment degrade. This degradation can lead to further arcing or short circuits, which release more energy and increase temperatures even more. - Release of Flammable Gases
When insulation materials or plastic components overheat, they can release gases as they decompose. These gases are often flammable, creating an additional hazard if they ignite. - Arcing and Sparking
The breakdown of insulation and the proximity of energized components can cause arcing or sparking between conductors. Arcing generates intense, localized heat that can further damage components and lead to rapid thermal escalation. - Formation of a Self-Propagating Reaction
As temperatures continue to rise, more materials degrade, creating a chain reaction where heat from one failing component accelerates the failure of others. This process becomes self-propagating, with each failure adding more heat to the system. - Fire and Potential Explosion
If the flammable gases and vaporized materials find an ignition source, they can ignite, leading to a fire within the electrical enclosure. In cases with high concentrations of gases or dust, an explosion may occur, posing serious hazards to nearby equipment and personnel. - Smoke and Toxic Fumes
Burning insulation, plastics, and other materials release toxic fumes, such as carbon monoxide and hydrogen chloride, which can spread through the facility. These fumes are hazardous to personnel and can trigger alarms or other safety systems, further disrupting operations. - Loss of Electrical Functionality
As components fail, the electrical equipment’s ability to control and distribute electricity is compromised. This can lead to an interruption of power to critical systems, potential grid instability, or further cascading failures in connected equipment.
The UltraSense Power Generation Solution
The key to preventing a failure chain reaction in electrical equipment is immediate detection of problems that allows operators time to take corrective action. UltraSense’s suite of sensors provide operators with early warning that can prevent a failure chain reaction from occurring or enables the ability to detect it at its incipient stage allowing other mitigation measures.
Prevention
The best way to avoid a failure chain reaction is to prevent it from happening in the first place. By monitoring the environment inside of the electrical enclosure, operators can take action to prevent conditions from developing that can lead to a failure chain reaction. With UltraSense sensors, operators can monitor:
- Temperature
- Humidity
- Particulates in the air
- Water ingress
When electrical equipment is exposed to high temperatures, high humidity, water ingress, or excessively dusty environments, they are more prone to failure. UltraSense sensors can monitor all of these parameters, or any subset of them, providing operators with the opportunity to mitigate the issue(s) and prevent a serious incident.
A key component of monitoring the health of electrical equipment is monitoring it for overheating. UltraSense provides versatility in how the temperature of electrical equipment is monitored. Operators can choose traditional contact-based temperature monitoring which assesses temperature at a particular location on the equipment. Or, they use IR thermography sensors, or a combination of the two.
IR thermography provides real-time monitoring of the equipment every two seconds, 24/7. Whereas traditional temperature sensors only provide the temperature of air around the sensor or the point where the probe attaches to equipment, IR thermography provides the temperatures of everything within its field of view.
UltraSense’s IR thermography sensors can greatly improve the maintenance posture of electrical equipment operators by eliminating the need for manual IR-gun inspections. On switchgear, when configured properly, IR thermography can be used to detect phase imbalance by detecting temperature differences between the phases which can lead to overheating.
Detection
Because a failure chain reaction in electrical equipment can transpire quickly before operators can mitigate issues, UltraSense also provides sensors that can detect it at the onset.
First, the IR thermography sensors can quickly report the rapidly increasing temperature. These sensors can be complemented with VOC/H2 (volatile organic compounds / hydrogen gas) detectors that sense the gases produced by the degradation of insulation and other plastic components. Lastly, an UltraSense smoke detector can also be installed inside of the enclosure.
Early detection of failure chain reaction conditions allows operators to take decisive actions such as isolating the equipment and activating emergency shutdowns or cooling systems.
UltraSense Sensor Features
UltraSense sensors are ruggedly built and are U.L. listed. The plug-and-play units can be used as standalone sensors or daisy chained for broad coverage.
The IR thermography sensors are available depending on the field of view desired, i.e., extra small, small, medium, and large. Each sensor can be divided into four different logical temperature sensors, allowing the monitoring of different aspects of the electrical equipment within its field of view.
The UltraSense VOC and VOC/H2 detectors are calibration free and have a service life of up to 10 years or more, depending on the model chosen. Sensors are available that monitor VOC/H2, temperature, and humidity from a single unit.
Users of UltraSense sensors have a choice of how they receive data from the units. Data can be accessed over an internet connection or using open protocols and business management / network systems via one of these options:
- SNMP (Simple Network Management Protocol): A method often used in networking to retrieve data from devices.
- Modbus TCP: Another common protocol that allows data exchange over IP networks, typically used in industrial settings.
- MQTT (Message Queuing Telemetry Transport): A protocol designed for IoT (Internet of Things) that enables the sensor to send data directly to an IoT cloud service.
UltraSense sensors can help operators comply with NFPA 70B, Standard for Electrical Equipment Maintenance, which requires both continuous thermal monitoring and operating environment monitoring for electrical equipment.
The Stat-X® Fire Suppression Solution
A failure chain reaction in electrical equipment does not follow a set timeframe. It can occur in minutes or may take hours. This means there will not necessarily always be time to take action if an UltraSense sensor detects a problem such as overheating or off-gassing.
To ensure the best safety posture for electrical installations, operators should always plan for the worst-case scenario—a fire or explosion in the enclosure. Stat-X aerosol fire suppression is tested and proven to be highly effective in electrical equipment fires.
Stat-X units can be activated by a fire detection system or thermally activated when exposed to a preset temperature. Once activated, the condensed aerosol fills the space, suppressing the fire. Further, it remains suspended for several minutes providing reflash protection.
Stat-X has zero ozone-depletion potential, zero global-warming potential, and zero atmospheric life. This means that users can be certain that they will never be faced with costly system replacement issues which are becoming increasingly common with other fire suppression agents.
Conclusion
While most electrical equipment operates without incident during its lifecycle, there are those that do experience a failure chain reaction which leads to fires and explosions. Fireaway, with its line of UltraSense sensors and Stat-X fire suppression systems, offers a complete protection package that provides the highest level of safety available from any single supplier.
Contact Fireaway for more information on how you can provide the best level of protection for your electrical installations.