Overview
Lithium-ion battery energy storage systems (BESS) are increasingly being adopted by renewable energy operators for the storage of excess power produced during periods of low power consumption. The stored power is kept available and can be transferred onto the grid when power demand warrants its use.
This concept is being deployed on a global scale, and for the most part, works well and without incident. But as more and more BESS are integrated into renewable energy systems, the risks posed by lithium-ion BESS are also becoming increasingly apparent. Since 2018, the Electric Power Research Institute has documented 72 grid-scale lithium-ion BESS failure incidents globally.
When a lithium-ion BESS experiences a failure, the results are often dramatic, resulting in a large fire that is difficult to extinguish. These incidents have produced explosive environments inside of BESS containers, at least one of which caused injuries to the first responders when they opened the enclosure. As is often the case, the BESS operator is unaware of the battery failure until the incident has reached catastrophic conditions.

Fireaway is now offering a total fire protection solution for BESS operators through their new line of UltraSense™ sensors. Fireaway produces Stat-X®, a condensed aerosol fire suppression agent that is proven effective on lithium-ion BESS fire incidents. When UltraSense sensors are paired with the Stat-X fire suppression system, Fireaway offers operators a complete protection package that includes prevention, detection, and suppression.
Lithium-Ion Battery Failure
Before delving into the protection features provided by UltraSense sensors, it is important to understand how lithium-ion batteries fail. Lithium-ion batteries fail in four basic stages:
Stage 1: Anomaly Detection/Prevention
This initial stage is triggered by factors such as:
- Exposure to high temperatures
- Exposure to high humidity
- Exposure to excessively dusty environments
- Overcharging
- Physical damage
- Internal short circuits
These conditions cause internal heating and increase the battery’s temperature, which can begin to stress the electrolyte and electrodes.
Stage 2: Off-Gassing
As the temperature rises, the electrolyte (usually an organic solvent) starts to decompose, releasing volatile organic compounds (VOCs) such as hydrogen, methane, and ethylene.
Then, as pressure builds up inside the battery, it swells and increases the risk of venting or rupture.
Step 3: Thermal Runaway
If temperatures exceed a critical threshold (typically around 120-150°C or 248-302°F, depending on the battery chemistry), a self-sustaining exothermic reaction, known as “thermal runaway,” can begin.
During thermal runaway, the reaction within the cell generates even more heat, accelerating the decomposition of the electrolyte and releasing more flammable gases.
Stage 4: Propagation to Neighboring Cells (if in a pack)
In battery packs, the failure of a single cell can produce intense heat and flames that ignite adjacent cells, causing a cascading effect.
This propagation can escalate into a large-scale failure leading to an intense fire and possible explosion, especially if there are no cooling, containment, or fire suppression measures to stop the spread.
The UltraSense Solution
The key to preventing the catastrophic failure of a BESS is early detection of anomalies occurring within the battery. UltraSense’s suite of sensors provides BESS operators with early warning at each of the first three stages of lithium-ion battery failure.
Stage 1: Anomaly Detection/Prevention
The best way to avoid BESS failure is to prevent it from happening in the first place. By monitoring the environment inside of the BESS, operators can take action to prevent conditions from developing that can lead to battery failure. With UltraSense sensors, operators can monitor:
- Temperature
- Humidity
- Particulates in the air
When lithium-ion batteries are exposed to high temperatures, high humidity, or excessively dusty environments, they are more prone to failure. UltraSense sensors can monitor all three, or any subset of the three, providing operators with the opportunity to mitigate the issue and prevent a serious incident.
Stage 2: Off-Gassing
When a lithium-ion battery begins to fail, the first detectable event is off-gassing of the volatile electrolyte inside of the battery casing. The UltraSense VOC gas sensor provides the earliest detection of a battery failure, allowing operators to take immediate and decisive actions such as:
- Initiating a controlled shutdown
- Activating cooling systems
- Ventilating the BESS container
Stage 3: Thermal Runaway
As the battery enters thermal runaway, it produces larger and larger amounts of VOCs and hydrogen gas. Hydrogen gas is produced particularly in BESS with liquid cooling systems. Its detection is a significant indicator that a thermal runaway is or is about to occur. UltraSense offers two different VOC/H2 detectors which provide quick detection of these gases, again allowing operators the opportunity to take action such as isolating the failing battery from the energy supply.
UltraSense Sensor Features
UltraSense sensors are ruggedly built and are UL listed. The plug-and-play units can be used as standalone sensors or daisy chained for broad coverage. The UltraSense VOC and VOC/H2 detectors are calibration free and have a service life of up to ten years or more, depending on the model chosen. Sensors are available that monitor VOC/H2, temperature, and humidity from a single unit.
Users of UltraSense sensors have a choice of how they receive data from the units. Data can be accessed over an internet connection or using open protocols and business management / network systems via one of these options:
- SNMP (Simple Network Management Protocol): A method often used in networking to retrieve data from devices.
- Modbus TCP: Another common protocol that allows data exchange over IP networks, typically used in industrial settings.
- MQTT (Message Queuing Telemetry Transport): A protocol designed for IoT (Internet of Things) that enables the sensor to send data directly to an IoT cloud service.
UltraSense sensors can help BESS operators comply with the following NFPA requirements:
- NFPA 855: Standard for ESS and Lithium-Ion Battery Storage Safety
- NFPA 72: National Fire Alarm & Signaling Code
- NFPA 69: Explosion Prevention Systems
The Stat-X Solution
Battery failure leading to thermal runaway does not follow a set timeframe. It can occur in as little as two minutes, or, it can take hours or even days to transpire. This means there will not necessarily always be time to take action if a Stage 2 or 3 UltraSense sensor detects a problem such as off gassing.
To ensure the best safety posture for BESS applications, operators should always plan for the worst-case scenario—a fire in the container. Stat-X is tested and proven to be highly effective in lithium-ion battery installations.
Stat-X units can be activated by a fire detection system or thermally activated when exposed to a preset temperature. Once activated, the condensed aerosol fills the container, suppressing the fire. Further, it remains suspended for several minutes providing reflash protection.
Stat-X has zero ozone-depletion potential, zero global-warming potential, and zero atmospheric life. This means that users can be certain that they will never be faced with costly system replacement issues which are becoming increasingly common with other fire suppression agents.
Conclusion
While most BESS operate without incident during their lifecycle, there are those that do experience catastrophic battery failure leading to fires and explosions. Fireaway, with its line of UltraSense sensors and Stat-X fire suppression systems, offers a complete protection package which provides a high level of safety from a single supplier.
Contact Fireaway for more information on how you can provide the best level of protection for your BESS installation.